Your choices on this site

We store a few things on your device so the radio works. Only if you agree, we also remember your settings and count how the site is used. We do not use advertising cookies today. “Marketing” is off unless you allow it: then a small script from the third-party service Metricool helps us understand visits from social media. You can change your mind at any time with Cookie settings at the bottom of every page. Cookie Policy

CatchliteRadio
Ask Paul | National Electrical Code cover art

Ask Paul | National Electrical Code

Welcome to Ask Paul the podcast where nationally recognized electrical code experts answer your electrical code-related questions on a weekly podcast. Join us as we answer questions submitted on the www.PaulAbernathy.com website. Get answers from National Electrical Code Panel Members who give their own opinions to answering NEC-related questions. Please be sure to visit https://fasttraxtube.com and subscribe for a FREE ACCOUNT to listen to all our new podcasts starting March 1, 2024. Become a supporter of this podcast: https://www.spreaker.com/podcast/ask-paul-national-electrical-code--4971115/support .

A podcast cover with a progress bar showing where you stopped

Pick up right where you left off

  • Resume on any device
  • Progress saved on every episode
  • Plus every other Pro feature

From €2.49/month

Episodes

  • Let's Ask Paul | Episode 76 | Voltage Drop Why, HCF Receptacle Locations, and Myers Hubs

    Aug 8, 2022 · 54m

    Resume with Pro

    Welcome to another episode of Let's Ask Paul, the podcast dedicated to answering your questions on the National Electrical Code. On this episode Paul Abernathy, CEO and Founder of Electrical Code Academy, Inc. answers questions about receptacles in health care facilities and their placements, Myers hubs, and a deep understanding of Voltage Drop and the increasing of the equipment grounding...

  • Let's Ask Paul | Episode 75 | Number of branch circuits on 15 or 20 and more.

    Aug 3, 2022 · 25m

    Resume with Pro

    Listen as Paul Abernathy answers more questions submitted via PaulAbernathy.com. In this episode Paul answers questions on how to calculate the minimum number of receptacles on branch circuits. Become a supporter of this podcast: https://www.spreaker.com/podcast/ask-paul-national-electrical-code--4971115/support .

  • Let's Ask Paul | Episode 74 | Cabin Disconnects, GFCI and Dryer Issue, and Lutron Panels

    Aug 3, 2022 · 34m

    Resume with Pro

    Listen as Paul Abernathy answers more questions submitted via PaulAbernathy.com. In this episode Paul answers questions on GFCI issued with Dryer, installing an outside service disconnect for a cabin and multiple Lutron panels and possible tap rules. Become a supporter of this podcast: https://www.spreaker.com/podcast/ask-paul-national-electrical-code--4971115/support .

  • Let's Ask Paul | Episode 73 | SEU and Bare Conductors and Rods at Detached Structure

    Jul 25, 2022 · 34m

    Listen as Paul Abernathy answers more questions submitted via the Let's Ask Paul Portal at www.PaulAbernathy.com . Today's question is about what do to when a service panel becomes a remote distribution panel (Subby Bruh) and it has existing SE-U cables. Paul will also answer a question about ground rods at a detached structure as well in this episode. Become a supporter of this podcast...

  • Let's Ask Paul | Episode 72 | Can GFCI's protect circuits with no EGC to Receptacles?

    Jul 16, 2022 · 31m

    Listen as Paul Abernathy, Certified Master Electrical Code Professional and CEO and Founder of Electrical Code Academy, Inc. answer more questions submitted through the Let's Ask Paul Portal at www.PaulAbernathy.com . In this episode Paul gets asked if a GFCI Device, such as a circuit breaker type or receptacle type OK to protect the branch circuit and receptacle when a non-grounding type is...

  • Let's Ask Paul | Episode 71 | WR on USB Devices, Apology OK, Raceway Studs and more

    Jul 16, 2022 · 24m

    Listen as Paul Abernathy, Certified Master Electrical Code Professional and CEO and Founder of Electrical Code Academy, Inc. answer more questions submitted through the Let's Ask Paul Portal at www.PaulAbernathy.com . This episode answer the questions about WR Rated Receptacles in damp or wet locations, does Paul accept a former trouble makers apology, and are stud packs, ganged studs, considered...

  • Let's Ask Paul | Episode 70 | 12 AWG and its amps, Motor Tables, and More

    Jul 9, 2022 · 27m

    Join Paul Abernathy for another episode of Let's Ask Paul from www.PaulAbernathy.com . In this episode, Paul answers the question of using motor nameplates versus the tables for full load current, and someone asks about the ampacity of a 12 AWG conductor and how to use the various NEC rules. Become a supporter of this podcast...

  • Let's Ask Paul | Episode 69 | Helping answer a Real World Transformer Sizing Request

    Jul 4, 2022 · 51m

    Listen as Paul Abernathy, CEO and Founder of Electrical Code Academy, Inc. answers another question from a submission via the Let's Ask Paul Portal at www.PaulAbernathy.com . This podcast answers a question about sizing a transformer to handle a single HVAC Load and all the things to take into consideration when selecting the proper sized transformer. Become a supporter of this podcast...

  • Let's Ask Paul | Episode 68 | Verifying an Electrician's Code References for Fire Incident

    Jun 26, 2022 · 41m

    Join Paul Abernathy, CEO, and Founder of Electrical Code Academy, Inc., a premier electrical code training academy located in Texas. Today's question was submitted through the Let's Ask Paul Portal at www.PaulAbernathy.com and it pertains to validation of NEC code references for a fire incident being inspected by the electrician or electrical inspector. Remember, you can submit your own questions...

  • Let's Ask Paul | Episode 67 | (2) 100A Panels supplied by 125A Main & More

    Jun 26, 2022 · 46m

    Join Paul Abernathy, CEO, and Founder of Electrical Code Academy, Inc. as he answers another question from those submitted via PaulAbernathy.com and the Let's Ask Paul Portal. In this episode, Paul answers the question about (2) 100 Amps breakers in a 125A Panel as well as explains straight versus slash-rated circuit breakers. Become a supporter of this podcast...

  • Let's Ask Paul | Episode 66 | Metal Boxes and Equipment Bonding Jumper Question

    Jun 19, 2022 · 22m

    Listen as Paul Abernathy, CEO and Founder of Electrical Code Academy, Inc. answers another question submitted via the Let's Ask Paul Portal at www/PaulAbernathy.com. Today's question was about using an equipment bonding jumper from the metal box to the device instead of taking an equipment bonding jumper from the equipment grounding conductor wirenut where all the EGC's are connected. Become a...

  • Let's Ask Paul | Episode 65 | Paul and Special Guest Jay Talk Schneider Recall

    Jun 17, 2022 · 40m

    Join Paul and his special guest Jay "The Basement King" Grundberg on this special episode of Let's Ask Paul as they talk about the recent news of the 1.4 Million Load Center Recall by Schneider Electric. Listen to Kickin' it with the KING podcast at https://anchor.fm/thebasementking Become a supporter of this podcast...

  • Let's Ask Paul | Episode 64 | So you wanna be a Electrical Inspector

    Jun 11, 2022 · 22m

    Listen as Paul Abernathy, CEO and Founder of Electrical Code Academy, Inc. answers more electrical code-related questions from folks who submit questions on the Let's Ask Paul Portal a www.PaulAberanthy.com . Today's podcasts answer a question asking for advice on becoming an electrical inspector. Become a supporter of this podcast...

  • Let's Ask Paul | Episode 63 | Ampacity of NM Cable and Subby's Bruh at Detached Garages

    Jun 11, 2022 · 40m

    Listen as Paul Abernathy, CEO and Founder of Electrical Code Academy, Inc. answers more electrical code-related questions from folks who submit questions on the Let's Ask Paul Portal a www.PaulAberanthy.com . Today's podcasts answer a question about the ampacity of Nonmetallic-sheathed cable and another about installing remote distribution panels, sometimes called sub-panels, in detached garages...

  • Let's Ask Paul | Episode 62 | Questions on Exam Prep, Neutral Colors, and Temporary NM Cable

    May 20, 2022 · 44m

    Listen as Paul Abernathy, Founder and CEO of Electrical Code Academy, Inc. and creator of the Fast Trax® National Electrical Code Learning System answers more questions submitted via PaulAbernathy.com at the Let's Ask Paul Portal. On this episode Paul answers questions on exam prep in the last 2 weeks, questions on stripes on neutrals, and using NM-B in a specific construction environment. Be...

  • Let's Ask Paul | Episode 61 | Sizing Conductors to AC Motor Compressor

    May 14, 2022 · 25m

    Listen as Paul Abernathy, CEO, and President of Electrical Code Academy, Inc. answers another question submitted via the portal at www.PaulAbernathy.com . This episode answers a submission about conductor sizing for motor compressors for air conditioning systems using the 2020 National Electrical Code. Become a supporter of this podcast...

  • Let's Ask Paul | Episode 60 | Explaining Transformer Protection in 450.3(B)

    May 14, 2022 · 1h 13m

    Listen as Paul Abernathy, CEO, and President of Electrical Code Academy, Inc. answers another question submitted via the portal at www.PaulAbernathy.com . This episode addresses the overcurrent protection rules for transformers found in 450.3(B) of the 2020 National Electrical Code. Become a supporter of this podcast...

  • Let's Ask Paul | Episode 59 | Understanding 150V or less to ground and 150V or more to ground

    May 8, 2022 · 17m

    Join Paul Abernathy, CEO and Founder of Electrical Code Academy, Inc. and the creator of the Fast Trax® NEC Learning System. On this episode of Let's Ask Paul, the discussion is about understanding the phrase 150 volts or less to ground and when it says 150 volts or more to ground in the National Electrical Code. If you are interested in the Fast Trax® NEC Learning System to increase your...

  • Let's Ask Paul | Episode 58 | Receptacle Spacing, Bus Ratings, and Ranges

    May 8, 2022 · 28m

    Join Paul Abernathy, CEO and Founder of Electrical Code Academy, Inc. and the creator of the Fast Trax® NEC Learning System. On this episode of Let's Ask Paul, the discussion is about kitchen receptacle spacing, range calculations on an electrical exam and so much more. If you are interested in the Fast Trax® NEC Learning System to increase your knowledge of the National Electrical Code then...

  • Let's Ask Paul | Episode 57 | Conductors at Subby's Bruh and Straight/Slash Rated Breakers

    May 2, 2022 · 38m

    Listen as Paul Abernathy, CEO and Founder of Electrical Code Academy, Inc. answer questions submitted on PaulAbernathy.com at the Let's Ask Paul. On this episode we answer questions about conductors to remote panels and chats on slash versus straight ratings. Also you can submit your questions to www.PaulAbernathy.com Become a supporter of this podcast...

  • Let's Ask Paul | Episode 56 | Our Present and Future Students - You Are Why We Do This!

    Apr 25, 2022 · 20m

    Listen as Paul Abernathy, CEO and Founder of Electrical Code Academy, Inc. answers another question submitted via the Let's Ask Paul Portal at www.PaulAbernathy.com . This episode is dedicated to Paul and his heartfelt message to his past, current, and future students. The funding of Electrical Code Academy, Inc. was not about the money. It was about the ability to teach others on a platform that...

  • Let's Ask Paul | Episode 55 | Why we don't just drive ground rods everywhere, like for Receptacles

    Apr 25, 2022 · 20m

    Listen as Paul Abernathy, CEO and Founder of Electrical Code Academy, Inc. answers another question submitted via the Let's Ask Paul Portal at www.PaulAbernathy.com . This episode is dedicated to a question being asked about why an EGC is needed at receptacles and why you just don't drive ground rods at receptacles rather than installing an equipment grounding conductor. This episode address the...

  • Let's Ask Paul | Episode 54 | Three Gang and Larger Box Support and More

    Apr 25, 2022 · 44m

    Listen as Paul Abernathy, CEO and Founder of Electrical Code Academy answers more submitted questions from the Let's Ask Paul Portal at www.PaulAbernathy.com . In this episode Paul answers questions on box supports, and of course the old 3' EMT Support debates again. Paul also answers a few other questions in this episode as well so tune in to see what gets asked...you never know if the question...

  • Let's Ask Paul | Episode 53 | Wago's and BackStabbing....Ok Haters....LOL

    Apr 17, 2022 · 25m

    Join Paul Abernathy, CEO and Founder of Electrical Code Academy, Inc., a premier provider of electrical exam preparation training and post licensing electrical code education as he answers a question about the use of WAGO's and backstabbing receptacle devices. For more information on Electrical Code Academy, Inc. visit www.ElectricalCodeAcademy.net to see our programs and try our demos. Become a...

  • Let's Ask Paul | Episode 51 | Multiwire Branch Circuits, Pigtails, and Listed Wall Mounted Devices

    Apr 17, 2022 · 19m

    Join Paul Abernathy, CEO and Founder of Electrical Code Academy, Inc., a leading electrical educational provide for learning the National Electrical Code as he answers more questions from PaulAbernathy.com. On this episode Paul answers (3) questions, one about a single receptacle outlet as a junction for multiple branch circuits, another about using all the terminals on a duplex receptacle or...